Technical Specifications:
Microphone Inputs:
- Two inputs, suitable for use with electret microphones
- DC powering for electret capsules
- VOX control from input 1
Line Input:
- Impedance 60KW each side, 20W differential
- Sensitivity: matched to normal SCART signal levels
Loop Current:
- 4 Amp Peak signal current into a SINGLE TURN loop
- Monitoring via front panel LED, which indicates current peaks
Loop Resistance:
- Must be less than 1W but greater than 0.3W.
Area Coverage:
- Nominal area of coverage is 60m² / 650 ft²
- Where metal is present, significant losses may occur reducing coverage area and affecting frequency response
Compression / AGC Control:
- Compression range from 36dB to overload
- Front panel indication
- Attack and Decay time constants optimized for speech
Frequency Response:
- 80 Hz to 5 KHz ±1.5dB at low level, measured as loop current
- High frequency high signal level response is a dynamic variable and is a function of loop size, loop current and signal content to ensure that no RFI generation takes place
- Internal time constants are very short
AC Power Input:
- 110-120 Volt AC, 50 - 60 Hz or 230 Volts AC, 45 - 65 Hz
- 15 VA Max power consumption
DC Power Input:
- 12V DC is available on the ILD60DC model
- 18 VA Max power consumption
Dimensions:
- Length: 216 mm / 8.5 in
- Width: 124 mm / 4.9 in
- Height: 44 mm / 1.8 in
Weight:
- 1.3Kg (2.9 Lb)
Accessories supplied:
- 1 microphone (10mm diameter) Tieclip style standard issue
- 1 cable, SCART to 2 Phono
- 1 AC input power cable
- EM195 A Desktop microphone / Q400 Boundary microphone optional
The AMPETRONIC ILD60 Induction Loop Amplifier carries a 5 year warranty.
Copyright © 1999 AssistiveAudio. All rights reserved.
Information in this document is subject to change without notice.
Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.